服务热线:023-68625759
关闭
copyright © 重庆永长科技有限公司 渝ICP备2021007358号
  • 管材检测系统MultiScan MS5800系列
管材检测系统MultiScan MS5800系列

管材检测系统MultiScan MS5800系列 这是一款可利用涡流、漏磁、远场及IRIS超声技术的多技术检测系统。 The MultiScan MS5800 is a multi-technology system offering these technologies: Eddy Current Magnetic Flux Leakage Remote Field IRIS Ultrasound

产品简介


这是一款可利用涡流、漏磁、远场及IRIS超声技术的多技术检测系统。
The MultiScan MS5800 is a multi-technology system offering these technologies:
Eddy Current
Magnetic Flux Leakage
Remote Field
IRIS Ultrasound
Tube Inspection with Eddy Current Testing (ECT)
Tube Inspection with Internal Rotating Inspection System (IRIS) for Ferrous and Nonferrous Materials
Tube Inspection with Remote Field Testing (RFT)
Tube Inspection with Near Field Testing (NFT)
Tube Inspection with Magnetic Flux Leakage (MFL)
MS 5800E
Tube Inspection with Eddy Current Testing (ECT)

MS5800Condensers
Feedwater heaters
Heat exchangers
Air conditioners
Eddy Current DiagramEddy current testing is a noncontact method used to inspect nonferromagnetic tubing. This technique is suitable for detecting and sizing metal discontinuities such as corrosion, erosion, wear, pitting, baffle cuts, wall loss, and cracks in nonferrous materials.Eddy Current DiagramTwo coils are excited with an electrical current, producing a magnetic field around them. The magnetic fields penetrate the tube material and generate opposing alternating currents in the material. These currents are called eddy currents.
Any defects that change the eddy current flow also change the impedance of the coils in the probe.
These changes in the impedance of the coils are measured and used to detect defects in the tube.
MultiScan MS 5800E Key Features
Four simultaneous frequencies per input.
This feature allows for inspection speeds up to 2 m/s with four frequencies on absolute and differential channels, without signal distortion.
Electronic probe balancing.
No separate external reference probe is required for absolute channel operation.
4 ECT inputs and up to 64 multiplexed channels.
The MultiScan™ MS 5800E can support a large number of ECT channels to perform array probe inspections. Compared to single-channel inspection, the array probe technology allows for faster and easier surface coverage.
MS 5800U
Tube Inspection with an Internal Rotating Inspection System (IRIS) for Ferrous and Nonferrous MaterialsMS5800Boilers
Feedwater heaters
Air coolers
Heat exchangersIRISThe ultrasonic IRIS option is used to inspect a wide range of materials, including ferrous, nonferrous, and nonmetallic tubing. This technique detects and sizes wall loss resulting from corrosion, erosion, wear, pitting, cracking, and baffle cuts. Olympus digital IRIS inspection technology is used extensively as a prove-up technique for remote field testing, magnetic flux leakage, and eddy current inspections.
IRISMultiScan MS 5800U (IRIS) Key Features
Setup wizard
Simplifies equipment calibration for different tube diameters and materials. The wizard also generates the reporting code for the inspection.
Real-time gain and gate controls
UT settings can be modified during the C-scan acquisition for quick optimization of signal detection.
Real-time and continuous color C-scans
Reduces missed flaws with C-scan displays. To enhance the quality and appearance of your reports, include color maps and cross-section views of defects.
Full tube-length recording
Used to analyze data off-line, and to assess results with customers.
MS 5800R
Tube Inspection with Remote Field Testing (RFT)
MS5800Boilers
Feedwater heaters
Carbon steel heat exchangers RFTRemote field testing (RFT) is being used to successfully inspect ferromagnetic tubing such as carbon steel or ferritic stainless steel. This technology offers good sensitivity when detecting and measuring volumetric defects resulting from erosion, corrosion, wear, and baffle cuts.
Olympus remote field probes and the MultiScan™ MS 5800 are used all around the world to successfully inspect heat exchangers, feedwater heaters, and boiler tubes.
MultiScan MS 5800R Key Features (RFT)
RFT with up to four different frequencies and real-time mixes.
This feature provides more flexibility for mixing and defect validation. The detection and sizing of flaws at the support plate is made easier with multifrequency inspections and dual-driver operations.
RFT with frequencies ranging from 20 Hz to 250 kHz.
The high frequency available with the MultiScan MS 5800R™ extends RFT inspection to thin materials with low permeability, such as 400-series stainless steel, and other ferromagnetic alloys.
Tube Inspection with Near Field Testing (NFT)
Air coolers
Carbon steel heat exchangers RFTNear field testing (NFT) technology is a rapid and inexpensive solution intended specifically for fin-fan carbon-steel tubing inspection. This new technology relies on a simple driver-pickup eddy current probe design providing very simple signal analysis.
NFT is specifically suited to the detection of internal corrosion, erosion, or pitting on the inside of carbon steel tubing. The NFT probes measure lift-off or "fill factor," and convert it to amplitude-based signals (no phase analysis). Because the eddy current penetration is limited to the inner surface of the tube, NFT probes are not affected by the fin geometry on the outside of the tubes.
MultiScan MS 5800 R™
Tube Inspection with Magnetic Flux Leakage (MFL)
Feedwater heaters
Air coolers
Carbon steel heat exchangers MFLMagnetic flux leakage (MFL) is a fast inspection technique, suitable for measuring wall loss and detecting sharp defects such as pitting, grooving, and circumferential cracks. MFL is effective for aluminum-finned carbon steel tubes, because the magnetic field is almost completely unaffected by the presence of such fins.
Eddy Current Array Multiplexer
Eddy Current Array MultiplexerThe array technologies are highly valuable when high resolution or imagery is desired. The MultiView acquisition and analysis software features improved C-scan functionality for easy setup and analysis in a virtually unlimited number of layouts.
When used in combination with the MS5800 and the MultiView "C" option, one or two ECA multiplexer units enable array technology with ECT, RFT, NFT, or MFL technologies. While the majority of OmniScan ECA probes can be connected to the ECA multiplexer, Olympus provides the option of configuring the Tube Testing Array probes to your needs.
MS 5800 BackpackMS 5800 BackpackEach MS5800 is currently delivered with the acclaimed Backpack (20ED0074, U8764077), which provides your operational staff with maximum comfort and protection. The Backpack, which was developed and tested in the field with the assistance of several service companies, also provides additional space to carry calibration tubes, probes, or adaptors.

MS 5800 Footswitch

MS 5800 footswitchThe optional MS5800 Footswitch (TA-FSW-001, U8770248) provides productivity gains to individuals or two-person crews when recording data. With its field-proven, rugged design, it enables the operator to remotely perform the majority of common operations by programming several useful and configurable functionalities in the MultiView software, without the need to directly access the computer.
相关推荐